Model | HD-90 | ||
Working pressure: | 8bar | 10bar | 12bar |
Air Delivery (m³/min) | 15 | 13.8 | 12.3 |
Air Delivery (CFM) | 530 | 488 | 435 |
Motor power | 90KW/120HP | ||
Power voltage: | 380V/50hz/3phase (different voltage is available) | ||
Compressor type: | Fixed Speed Rotary Screw Air Compressor | ||
Cooling Mode | Air cooling | ||
Starting mode | Star-delta Start | ||
Ambient temperature | -5℃ ~ +45℃ | ||
Discharge temperature | ≤ Ambient temperature+15℃ | ||
Dimension (mm) | 2000*1250*1670 |
Product display: |
Product advantage: |
1.Air compressor adopts world-renowned components contributing to guarantee the compressor longer service life.
2.Smart touch screen design and 0 pressure drop design.
3.Higher efficient cooling system and electrical motor.
4.Stainless steel pipes, reasonable inner design.
Several precautions for the use of cold dryers?
1. Do not place in the sun, rain, wind or places where the relative humidity is greater than 85%, do not place in an environment with a lot of dust, corrosive or flammable gas, and do not place in an environment where there is vibration or condensation, which is dangerous to freeze. The place. Don’t be too close to the wall to avoid poor ventilation. It must be used in an environment with deer corrosive gas. A desiccator with rust-proof copper tube or a stainless steel heat exchanger-type desiccator should be used, and the ambient temperature should be 40°C. Used below.
2. Do not connect the compressed air inlet wrongly. To facilitate maintenance, a bypass pipeline should be provided to ensure maintenance space. It is necessary to prevent the vibration of the air compressor from being transmitted to the dryer. Do not add the weight of the piping directly to the dryer. 120HP Rotary Air Compressor
3. Do not stand the drain pipe upwards, do not fold or squash it.
4. The allowable fluctuation of power supply voltage is less than ±10%. An appropriate capacity leakage circuit breaker should be installed, and it must be grounded before use.
5. The temperature of the compressed air inlet is too high, the ambient temperature is too high (above 40℃), the use flow exceeds the rated processing air volume, the voltage fluctuation exceeds ±10%, and the ventilation is too poor (ventilate in winter, otherwise the room temperature will also increase ), etc., the protection circuit will work, the indicator light will be off, and the operation will stop.
6. When the air pressure is higher than 0.15MPa, the drain port of the normally open automatic drain can be closed. The displacement of the air compressor is too small, the drain is open, and air is blown out. 120HP Rotary Air Compressor
7. The quality of compressed air is poor. If dust and oil are mixed, these stolen goods will stick to the heat exchanger, reducing its working efficiency, and the drainage is also prone to failure. It is hoped that a filter should be installed at the inlet of the dryer, and it is necessary to confirm whether the water is drained a day. Less than once.
8. The vent of the dryer should be cleaned with a vacuum cleaner once a month.
9. Turn on the power supply, and when the running state is stable, turn on the compressed air again. After stopping the operation, you must wait for more than 3 minutes before restarting.
10. If you use an automatic drain, you should always check whether its drainage function is normal, and often clean the dust on the condenser. Check the pressure of the refrigerant frequently to determine whether the refrigerant is leaking and whether the capacity of the refrigerator has changed. It is necessary to check whether the temperature of the condensed water is normal. 120HP Rotary Air Compressor
Company introduction |
Production Capability |
Corporate Qualifications |
Global exhibition & Training |
Packing and delivery |
Hot Tags: 120HP Rotary Air Compressor, China, manufacturers, suppliers, factory, customized, wholesale, in stock, Variable Frequency Screw Air Compressor, 10bar Vsd Screw Air Compressor, Frequency Air Compressor, Energy Saving VSD Air Compressor, 10hp 7 5kw Rotary Air Compressor, VFD Three phase Motor Compressor