Screw Compressor Maintenance

Screw Compressor Maintenance

18.5KW 25HP fixed speed rotary screw compressor Specification
Model: HD-18D5
Power: 25HP/18.5kw
Working pressure: 8bar - 12bar
Air delivery: 3m³/min (106cfm)
Power voltage: 380V/50hz/3phase (different voltage is available)
OEM & ODM service support.

Product Introduction
ModelHD-18D5
Working pressure:8bar10bar12bar
Air Delivery (m³/min)32.22
Air Delivery (CFM)1067871
Motor power18.5KW/25HP
Power voltage:380V/50hz/3phase (different voltage is available)
Compressor type:Fixed Speed Rotary Screw Air Compressor
Cooling ModeAir cooling
Starting modeStar-delta Start
Ambient temperature-5℃ ~ +45℃
Discharge temperature≤ Ambient temperature+15℃
Dimension (mm)1380*850*1160


Product display:


Product advantage:

1. Show obvious energy-saving advantages in small air volume.

2. Frequency range from 0%-100% (common conversion from 60%-100%).

3. Energy saving can up to 22%-40% compared with the fixed speed compressor.

4. Fast heat dissipation.

What should I do when the air compressor fails to start? screw compressor maintenance

1. Check the power supply. If the power supply is not turned on, you can turn on the power switch to turn on the power.

2. The control circuit fuse is blown: the fuse needs to be replaced immediately to find out the cause and solve it.

3. The thermal overload relay is disconnected: correct the cause of the overload and reset the thermal overload electrical appliances.

4. If the voltage is too low, please ask the power department to check the input voltage and compare it with the motor terminal voltage to check the reason for the low voltage.

5. Whether it is a power failure, you need to check the power supply part at this time.

6. Is it because the wiring is loose? At this time, you should check all the wiring terminals and tighten them if there is any looseness. screw compressor maintenance

7. Temperature sensor failure: the sensor needs to be checked. If there is a failure, you need to contact professional maintenance personnel for repair.

8. Transformer failure: check the secondary voltage of the transformer.

9. The thermal overload relay is disconnected: correct the cause of the overload and reset the thermal overload electrical appliances. screw compressor maintenance

Company introduction

01

Production Capability

3.0

Corporate Qualifications

Global exhibition & Training

Packing and delivery

(1)

Hot Tags: screw compressor maintenance, China, manufacturers, suppliers, factory, customized, wholesale, in stock, Electric Air Screw Compressor 75kw, 15hp Screw Air Compressor, Regular Model Screw Air Compressor, Small Belt Drive Screw Compressor 7 5kw, Stationary Regular Screw Compressor, Industrial air compressor