Analysis of lubricating oil inlet failure of permanent magnet variable frequency air compressor

Jun 13, 2019Leave a message



1, condensation water accumulation caused by oil level reading error

According to the operation requirements of the permanent magnet variable-frequency air compressor, the air compressor should be provided with a minimum running time to prevent the formation of condensed water, because condensed water will cause rust of cylinder valve plates, rack parts, etc.Accumulation of condensed water in the crankcase may cause errors in oil level readings.Water and oil do not mix, and their co-existence causes oil to deteriorate rapidly.Minimum operating time is generally not less than 10min, should be enough to make the air compressor heating to gasification condensation moisture.At present, the running time of air compressor is all 7min, which obviously cannot meet the requirements.

ca1349540923dd5435c7a31edf09b3de9c82480b

2. The exhaust water content of the permanent magnet variable-frequency air compressor exceeds the standard seriously

Due to the long shutdown time of the permanent magnet variable-frequency air compressor, the moisture generated by exhaust accumulates around the pipeline and check valve, leading to water backflow to the inside of the chassis, and the moisture content of lubricating oil gradually increases, which eventually leads to the alarm of the oil level of the permanent magnet variable-frequency air compressor and the fault shutdown.When the outlet pipeline of the air compressor was removed after shutdown, milky white liquid was found to be flowing out of the pipeline, indicating that the exhaust water content of the permanent magnet frequency conversion air compressor was seriously exceeding the standard.


3. The gas-water separator cannot separate the moisture generated in the compression process very well

Permanent magnet frequency conversion air compressor export pipeline equipped with check valve, high temperature and high pressure of the wet air through the air compressor exhaust valve, after level after cooler is with some oil, water composition, while permanent magnet between the secondary and tertiary level of frequency conversion air compressor cooler and final cooler after all have spirit with water separator, compression process for separation of the water, but the actual running effect is not ideal.