15 22 37 45kw Energy Saving 35% (EVA) Non-Inductive Pm VSD Screw Air Compressor Price

15 22 37 45kw Energy Saving 35% (EVA) Non-Inductive Pm VSD Screw Air Compressor Price

Variable frequency air compressor is one of the screw air compressor, here is an important part is inverter, frequency converter is a part of a driving system, in which the important components include ac motor, drive controller (that is, frequency converter) itself and the operation interface...

Product Introduction

Over the years, the company has been committed to the design, manufacturing and sales for Air Filter Element For Air Compressor, PM Type Rotary Screw Compressor, Heavy Screw Air Compressor. On the track of international development, we are constantly pursuing common development with employees, value creation with customers and prosperity with society. Our company has many years of production management experience, we are familiar with the international standard product process. Active communication and cooperation with peers and improved innovation capacity are the driving force behind the sound and stable development of our company.

ModelHD-VPM55
Working pressure:8bar10bar12bar
Air Delivery (m³/min)9.28.27.1
Air Delivery (CFM)325290251
Motor power55KW/75HP
Power voltage:380V/50hz/3phase (different voltage is available)
Compressor type:Permanent Magnet Variable Frequency Screw Air Compressor
Cooling ModeAir cooling
Starting modeVariable Frequency Start
Ambient temperature-5℃ ~ +45℃
Discharge temperature≤ Ambient temperature+15℃
Dimension (mm)1800*1250*1670
Product display:


Product advantage:

1. The permanent magnet motor remains high efficiency at low speeds.

2. Equipped with intelligent micro computer system.

3. Compared with the fixed speed compressor, energy saving 22%-40%.

4. Adopt high efficiency cooling system.

5. The larger system volume fluctuations, the more obvious energy-saving effect.

Energy-saving principle of air compressor soft start

Air compressor soft start is divided into two types: one is to start with variable frequency constant torque and current limit; the other is to start with thyristor voltage regulation, also known as intelligent soft start.

1. Comparison of two types of soft start

①Technical performance. It adopts variable frequency speed regulation to start, which has good static and dynamic performance when starting. Even at low speed, the motor torque can be adjusted at will, and the motor can be started with constant torque. The starting current can be limited to the rated current below the rated current. Intelligent Soft start, because the torque is reduced according to the second power of the voltage ratio when starting, the starting torque is very small, the soft starter has current feedback, and constant current starting can also be used, that is, keeping the starting current constant during the starting process , Until the motor is close to the synchronous speed. In terms of technical performance, variable frequency speed regulation start is suitable for loads with larger starting torque, which are generally larger than occasions, such as reciprocating air compressors, centrifugal separators, loaded conveyors, crushers, screw types or Rotary air compressors, centrifugal fans, centrifugal pumps, no-load starting conveyors and various no-load starting equipment. compressor low pressure

②Economical, the investment cost of using frequency converter to adjust speed is twice or even three times higher than that of intelligent soft start.

Based on the above technical performance and economy, the starting method that can be actually promoted by industrial and mining enterprises is the latter.

2. Smart soft starter

The intelligent soft start is mainly composed of a voltage regulating circuit composed of three pairs of anti-parallel thyristors connected in series between the power supply and the controlled motor. The microprocessor is the control core. The whole start process is automatically carried out under the control of digital program software. The starter uses the electronic switching characteristics of three pairs of thyristors, and the microprocessor in the starter controls the trigger pulse to change the trigger delay angle. The trigger delay angle of the thyristor can change the conduction time of the thyristor. , So that z* finally changes the magnitude of the three-phase voltage added to the stator windings. The characteristic of asynchronous motor stator voltage regulation is that the motor torque is approximately proportional to the square of the stator voltage, and the current of the motor is proportional to the stator voltage. , The starting torque and initial current limit of the motor can be achieved through the control of the stator voltage. The motor stator voltage is controlled by the conduction angle of the thyristor, so different initial phase angles can achieve different terminal voltages to meet different load starting characteristics. During the start of the motor, the conduction angle of the thyristor gradually increases, and the output voltage of the thyristor also gradually increases. The motor accelerates from zero until the thyristor is fully turned on and the start is completed, thus realizing the stepless smooth start of the motor. The z* maximum value of the starting torque and starting current can be set according to the load condition. compressor low pressure

Basic characteristics of intelligent soft starter

1) Adopting microprocessor full digital self-control monitoring, the starting current rises steadily with a constant slope when starting, there is no impulse current to the grid, and no large voltage drop is caused, ensuring the stability of the grid voltage, starting torque, current, voltage , Time can be set according to different loads, can obtain z*best current impact and z*best torque control characteristics, which greatly reduces the impact of motor torque on the load, and also meets the starting torque of different work objects Different requirements to protect the driven mechanism.

2) The motor start is not affected by the fluctuation of the grid voltage. Due to the introduction of current feedback in the phase shift circuit of the thyristor, the motor maintains a constant current and starts smoothly during the starting process. At the same time, because the starting current is set as the fixed value, when the grid voltage fluctuates, the control circuit automatically increases or decreases the thyristor conduction angle to maintain the original set value, which can protect the constant starting current. Some soft starters also Using dual power isolation to ensure that the control part is not interfered by various strong currents.

3) According to the different working objects, the motor can choose a variety of start and stop methods, and different starting methods have different starting torques. Generally, the initial torque range of soft start of the motor is selected. From the initial torque, it can be started at the level of the starting torque according to user requirements. The stator voltage of the motor increases steplessly during the ramp acceleration time, and the acceleration ramp time is set by the user , The motor can stop freely and softly, the time of soft stop can be adjusted, and the characteristic of soft stop greatly prolongs the life of electrical contacts. compressor low pressure

4) Simple structure, light weight, no noise, small footprint, as a non-contact control, the service life of the soft starter is much longer than that of the traditional contactor. If used properly, it can be as long as several decades. Easy to install, operate and use. The smooth and gradual starting process of the soft starter can reduce the vibration and noise of the equipment, extend the life of the motor and the driven machinery, and improve the working environment of the workers.

5) Multiple protections such as overcurrent, overload and power failure can be selected to ensure the safety of equipment and motors. Soft start can provide fast fault diagnosis information for monitoring and protection of equipment, such as current limit, overload, phase failure, rotor lock, etc. The protection setting value can be specified by the user, and the protection performance is reliable. Some soft starters also have automatic phase sequence recognition. , Phase sequence protection function.

6) With standard RS-232C interface, with communication function. The intelligent soft starter transmits data through a standard interface, and can be integrated into a network to realize decentralized control and centralized management. Its all-digital setting and external control functions are greatly convenient for users, and the performance and price ratio are high. The intelligent soft starter has a friendly human-machine interface. It displays the operating voltage, operating current, maximum current when working, and displays the fault category when it is faulty. It has a convenient external control interface, with digital delay start control, soft stop control input, and start delay relay. Various functions such as output and fault relay output. compressor low pressure

Company introduction

01

Production Capability

3.0

Corporate Qualifications

Global exhibition & Training

Packing and delivery

(1)

Our company adheres to the theory of "systematic solution" to create exclusive 15 22 37 45kw Energy Saving 35% (EVA) Non-Inductive Pm VSD Screw Air Compressor Price solutions for our customers. We have sufficient experience in producing products according to samples or drawings. We often conduct joint reviews to find out the causes of anomalies and seek improvement measures to achieve cost control and improve performance.

Hot Tags: compressor low pressure, China, manufacturers, suppliers, factory, customized, wholesale, in stock, PM Double Stage Compressed Air Compressor, Oil-gas Separator, Screw Air Compressor, Power Frequency Air Compressor, 37kw PM Screw Air Compressor, AC Power Double Compression Air Compressor

Send Inquiry

whatsapp

Phone

E-mail

Inquiry