Pneumatic Circulation System

Dec 26, 2018Leave a message

When the compressor is working, the air is sucked through the self-cleaning air filter, and the filter is automatically cleaned by the PLC. After the air is automatically adjusted by the inlet guide vane, the air enters the first-stage compression, and the gas after the first-stage compression has a higher temperature, and then enters. The intercooler is cooled (in the water pipe, outside the gas pipe, the water flow requirement of the intercooler is 110m/h) and then enters the secondary compression system to prevent the gas in the system from pouring into the compression chamber (avoid pressure start) A suspension full-back check valve is installed in the exhaust pipe of the compressor, and the gas discharged from the compressor pushes the check valve into the exhaust muffler, then enters the primary aftercooler, the secondary aftercooler, and then enters Exhaust main pipe.