4, no load empty car too long automatic shutdown system and restart time setting
If the amount of air used by the system is reduced, the compressor remains operating without load. If the no-load running time exceeds the set time, the air compressor will automatically stop and the motor will stop running. When the system's air usage increases, the system pressure will decrease, and the air pressure will automatically start to replenish the air volume. For the setting of the time when the no-load operation is too long, the air compressor controller has another setting, and the air compressor can be started again five minutes after the motor is stopped.
5, fault reset
After the inverter fails, the inverter will display the relevant fault information. The user can reset the fault through the Stop key on the keyboard or the terminal function (Group F4). After the inverter fault is reset, it is in the standby state. If the inverter is in a fault state, if it is not reset, the inverter is in the running protection state and the inverter cannot be operated.