The condensate discharge method should be carried out after the machine is shut down, there is no pressure in the oil and gas separation tank, sufficient cooling, and the condensed water is fully precipitated, such as before starting in the morning.

1. Open the bleed valve first to remove the air pressure.

2. Unscrew the front plug of the ball valve at the bottom of the oil and gas separation tank.

3. Slowly open the ball valve to drain until the oil flows out and close the ball valve.

4. Screw on the front of the ball valve.